Elemental Analyzer Systems Spare Parts

Miscellaneous Parts for Elemental Analyzers

 



 
Part No.
 
Nomenclature
 
10037
Furnace, 13" L, 115V/230V
10011
Membrane Dryer
10008
Lamp, UV
10227
Power Supply, BHK, UV Lamp
10077
Filter, Interference, Zinc Lamp
10001
Filter, Red, band pass
10007
Filter, Fluorescence, Blue, band pass
10219
Filter, UV, Sulfur GC Detector
10059
Filter, Disposable (between combustion tube & membrane dryer)
10299
Filter, Interference, Excimer
10224
PMT, Nitrogen R2228
10010
PMT, Sulfur
10002
Lens, Quartz
10143
Lens, Collimating 1"
10013
Cell Assembly, Ozone Generator, refurb (w/trade-in only plus 10% credit given)
10006
Thermoelectric Cooler, 12 Volt (nitrogen detector tray)
11177
Thermoelectric cooler, 12 Volt, Multi-Matrix block
10016
Septa, 12.5 mm, Teflon Faced, 100/pk
10017
Septa, 12.5 mm, Teflon Faced, 25/pk
10151
Septa, 12 mm, Teflon faced, 25 pk
10152
Septa, 12 mm, Teflon faced, 100 pk
10149
Septa, 11 mm, Teflon faced, 25 pk, Multi-matrix block lid
10150
Septa, 11 mm, Teflon faced, 100 pk, Multi-matrix block lid
10021
Ferrule, Teflon, 1/4", ea. (for elbow connection)
10051
Ferrule, Teflon, 1/4", 10/pk (for elbow connection)
10018
Ferrule Set (one front/one back), SS, 1/8"
10019
Ferrule Set (one front/one back), Brass, 1/8"
10099
Desiccant Capsule (for PMT housing)
10020
Light Boot Rubber 1/8"
10233
Light Boot Rubber 1/4"
10061
Moleculite Refill, 6-14 Mesh 1 lb.
10226
Drierite Refill, 1 lb.
10184
Kit, O-Ring, Sulfur Fluorescence
10185
Kit, O-Ring, Nitrogen Chemiluminescence
10182
O-Ring, 1 5/16" x 2 1/8" Nit Reaction Chamber
10205
O-Ring, Model 740 Inlet Hatch
10075
O-Ring, O-Ring, 1/16 x 3/16, Multi-Matrix Drive Rod
10106
O-Ring, Ozone Scrubber Tube
10178
O-Ring, UV O-Ring, 1" x .8", UV Block
10047
O-ring, ½" x 3/32" (for Combustion Tube)
10049
Teflon Tubing, 1/8" x qty length specified
10393
Sample Line Tubing Assy., 1/8" x 4', black, Membrane Dryer to Detector
10087
Clamp, Ball & Socket, #18 (for #10079 elbow)
10085
Insulator Pad, 1" sq. x 4" lg., Furnace Seal
10093
Thermocouple, platinel, dual leads, furnace
10100
Ferrule, Vespel (Furnace Thermocouple)
10107
Union, Reducing 1/4" x 1/8", SS
10146
Wool, Quartz 5 Grams
10098
Drive Rod (Rod Only), Multi-Matrix / Sample Drive
10208
MFC, Porter, Oxygen 0-50 ml/min
10210
MFC, Porter, Oxygen 0-500 ml/min
10262
MFC, Porter, Oxygen 0-1000 ml/min
10291
MFC, Porter, Argon 0-50 ml/min
10209
MFC, Porter, Argon 0-500 ml/min
10237
MFC, Porter, Hydrogen 500 SCCM
10213
MFC Cable, 15 Pin Male to 15 Pin Female (Redwood to Redwood)
10214
MFC Cable, 15 Pin Female to 9 Pin Female (Redwood to Porter)
10211
LCD, 9000 Tray Assembly (front panel display)
10212
Union, Male Brass, 1/8" NPT to 1/8" Swagelok
10215
Union, Male Brass, 1/8" NPT to 1/16" Swagelok
10216
Male Run Tee, Brass 1/8" NPT to 1/8" Swagelok
10217
Power Supply, +15, -15, +5 Vdc
10218
Power Supply, 12 Vdc
10220
PCI 1200 Nidaq PCB (communication with computer)
10229
Fan, Cooling 4 5/8" x 4 5/8"
10232
Fan, Cooling 3" x 3" Multi-Matrix
10102
Fan, Cooling 12 Vdc, Nitrogen TEC, PMT cooler
10239
Fuse 1A Detector Tray
10240
Fuse 2A Detector Tray
10241
Fuse 3A Detector Tray
10250
Bulkhead Fitting 1/8" Brass
10260
CAL 3200 Controller
10281
Stepper Motor, Syringe Drive
10304
Motor Controller, Syringe Drive
10341
Gas Filter with 1/8" Brass Fittings, filled with Molecular Sieve 5A and CoFree moisture indicator
 

Contact GenesisTC

Got questions? Need prices? Need more info?  Please “contact us” for prompt assistance

Antek Services

Featured Items

GenesisTC Offers

  • Same Quality Parts
  • Competitive Pricing
  • Typically In Stock

From the Owner:

 

Genesis The Company was conceived by Irvin Helder in 1996. Irvin worked into his eighties and was devoted to providing the highest quality of service to his clients. Irvin passed his business to me, Richard Hernandez, in January 2007, and I am doing my very best to provide the same quality and knowledgeable service to my clients as well. He did it because he cared about the folks he worked for, and I do it for the same reason. When I was the Service Manager for an analyzer manufacturer, my boss, who was also the owner of the company, instilled in me the importance of taking care of the customer to minimize their instrument's down time. I have been inspired by two great men who always put Customer Service first and who taught me to do the same.

Richard Hernandez
Owner